# Logging strategy
|
|
|
|
This document describes the overall logging strategy of NBC.
|
|
This is a suggested guideline, rare events can have a higher logging level
|
|
than suggested in the guideline for example at beacon node start or stop.
|
|
|
|
The main objectives are:
|
|
- INFO log level or higher should be suitable for long-term use, i.e. running for months or weeks. Logs are the users' main interface their beacon node and validators. In particular it should not be a denial-of-service vector, either by leading to high CPU usage of the console or filling disk space at an unsustainable rate.
|
|
- INFO logs or higher should be target at users, logs only relevant to devs should be relegated to DEBUG or TRACE or commented out.
|
|
- DEBUG log level should still be readable by visual inspection during a slot time (6 seconds).
|
|
|
|
Here is the suggestion of content per log level
|
|
|
|
- Fatal: Node will crash
|
|
- Error: Bugs or critical unexpected behaviors
|
|
- node cannot proceed with task
|
|
- node consistency is compromised
|
|
- Warning: Errors that can be expected or handled
|
|
- networking issue,
|
|
- node cannot proceed with task but can recover or work in degraded mode (invalid bootstrap address, out of Infura requests)
|
|
- Notice: Important user and validator info and one-time events
|
|
- node start/quit,
|
|
- log about validator funds,
|
|
- own PoS attestations,
|
|
- own PoS blocks,
|
|
- chain reached finality,
|
|
- validators have been slashed (i.e. might indicate malicious activity or network/chain split)
|
|
- Info: standard user target
|
|
- Networking or consensus information
|
|
- Debug: dev and debugging users
|
|
- Common networking activity (new peers, kick peers, timeouts),
|
|
- consensus/proof-of-stake various processing,
|
|
- Trace: dev only
|
|
- Keep-alive,
|
|
- routine tasks schedules
|
|
- "spammy" tasks that clutter debugging (attestations received, status/control messages)
|
|
|
|
Logs done at high frequency should be summarized even at trace level to avoid drowning other subsystems.
|
|
For example they can use an uint8 counter with
|
|
```
|
|
proc myHighFreqProc() =
|
|
var counter {.threadvar.}: uint8
|
|
if counter == 255:
|
|
trace "Total of 255 myHighFreqProc call"
|
|
counter += 1
|
|
```
|