fix slot number display during sync (#3383)
#3304 introduced a regression to the sync status string displayed in the status bar; during the main forward sync, the current slot is no longer reported and always displays as `0`. This patch corrects the computation to accurately report the current slot once more.
This commit is contained in:
parent
873a8ec1e6
commit
a28900c348
|
@ -591,7 +591,7 @@ proc syncLoop[A, B](man: SyncManager[A, B]) {.async.} =
|
||||||
else: InfiniteDuration
|
else: InfiniteDuration
|
||||||
currentSlot = Base10.toString(
|
currentSlot = Base10.toString(
|
||||||
if man.queue.kind == SyncQueueKind.Forward:
|
if man.queue.kind == SyncQueueKind.Forward:
|
||||||
min(uint64(man.queue.outSlot) - 1'u64, 0'u64)
|
max(uint64(man.queue.outSlot), 1'u64) - 1'u64
|
||||||
else:
|
else:
|
||||||
uint64(man.queue.outSlot) + 1'u64
|
uint64(man.queue.outSlot) + 1'u64
|
||||||
)
|
)
|
||||||
|
|